Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 91
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Tomography ; 10(2): 266-276, 2024 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-38393289

RESUMO

OBJECTIVE: Internal Jugular Vein Stenosis (IJVS) is hypothesized to play a role in the pathogenesis of diverse neurological diseases. We sought to evaluate differences in IJVS assessment between CT and MRI in a retrospective patient cohort. METHODS: We included consecutive patients who had both MRI of the brain and CT of the head and neck with contrast from 1 June 2021 to 30 June 2022 within the same admission. The degree of IJVS was categorized into five grades (0-IV). RESULTS: A total of 35 patients with a total of 70 internal jugular (IJ) veins were included in our analysis. There was fair intermodality agreement in stenosis grades (κ = 0.220, 95% C.I. = [0.029, 0.410]), though categorical stenosis grades were significantly discordant between imaging modalities, with higher grades more frequent in MRI (χ2 = 27.378, p = 0.002). On CT-based imaging, Grade III or IV stenoses were noted in 17/70 (24.2%) IJs, whereas on MRI-based imaging, Grade III or IV stenoses were found in 40/70 (57.1%) IJs. Among veins with Grade I-IV IJVS, MRI stenosis estimates were significantly higher than CT stenosis estimates (77.0%, 95% C.I. [35.9-55.2%] vs. 45.6%, 95% C.I. [35.9-55.2%], p < 0.001). CONCLUSION: MRI with contrast overestimates the degree of IJVS compared to CT with contrast. Consideration of this discrepancy should be considered in diagnosis and treatment planning in patients with potential IJVS-related symptoms.


Assuntos
Veias Jugulares , Doenças Vasculares , Humanos , Constrição Patológica/diagnóstico por imagem , Constrição Patológica/patologia , Veias Jugulares/diagnóstico por imagem , Veias Jugulares/patologia , Estudos Retrospectivos , Imageamento por Ressonância Magnética , Doenças Vasculares/patologia , Tomografia Computadorizada por Raios X
2.
Med Phys ; 50(11): 6844-6856, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37750537

RESUMO

BACKGROUND: Peripheral arterial disease (PAD) is a chronic occlusive disease that restricts blood flow in the lower limbs, causing partial or complete blockages of the blood flow. While digital subtraction angiography (DSA) has traditionally been the preferred method for assessing blood flow in the lower limbs, advancements in wide beam Computed Tomography (CT), allowing successive acquisition at high frame rate, might enable hemodynamic measurements. PURPOSE: To quantify the arterial blood flow in stenotic below-the-knee (BTK) arteries. To this end, we propose a novel method for contrast bolus tracking and assessment of quantitative hemodynamic parameters in stenotic arteries using 4D-CT. METHODS: Fifty patients with suspected PAD underwent 4D-CT angiography in addition to the clinical run-off computed tomography angiography (CTA). From these dynamic acquisitions, the BTK arteries were segmented and the region of maximum blood flow was extracted. Time attenuation curves (TAC) were estimated using 2D spatio-temporal B-spline regression, enforcing both spatial and temporal smoothness. From these curves, quantitative hemodynamic parameters, describing the shape of the propagating contrast bolus were automatically extracted. We evaluated the robustness of the proposed TAC fitting method with respect to interphase delay and imaging noise and compared it to commonly used approaches. Finally, to illustrate the potential value of 4D-CT, we assessed the correlation between the obtained hemodynamic parameters and the presence of PAD. RESULTS: 280 out of 292 arteries were successfully segmented, with failures mainly due to a delayed contrast arrival. The proposed method led to physiologically plausible hemodynamic parameters and was significantly more robust compared to 1D temporal regression. A significant correlation between the presence of proximal stenoses and several hemodynamic parameters was found. CONCLUSIONS: The proposed method based on spatio-temporal bolus tracking was shown to lead to stable and physiologically plausible estimation of quantitative hemodynamic parameters, even in the case of stenotic arteries. These parameters may provide valuable information in the evaluation of PAD and contribute to its diagnosis.


Assuntos
Angiografia por Tomografia Computadorizada , Tomografia Computadorizada Quadridimensional , Humanos , Angiografia por Tomografia Computadorizada/métodos , Constrição Patológica/diagnóstico por imagem , Artérias , Hemodinâmica , Extremidade Inferior , Angiografia Digital
3.
Clin Neuroradiol ; 33(3): 695-700, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36799990

RESUMO

BACKGROUND: Based on increased understanding of the idiopathic intracranial hypertension (IIH) pathophysiology, venous sinus stenting (VSS) has emerged as an effective treatment for patients with transverse sinus stenosis (TSS). The presence of a reliable TSS screening tool is warranted. The combined conduit score (CCS) is the most widely used score for evaluation of the cerebral sinovenous stenosis in contrast-enhanced magnetic resonance venography (CE-MRV). PURPOSE OF THE STUDY: To evaluate the interobserver agreement between neuro-interventionalists and radiologists with respect to the CCS in evaluation of transverse sinus stenosis in patients with idiopathic intracranial hypertension using CE-MRV. METHODS: A retrospective study was conducted on 26 consecutive patients diagnosed with IIH and underwent CE-MRV. The 2 neuro-interventionalists and 2 radiologists separately evaluated the cerebral venous sinuses using the CCS. RESULTS: The mean CCS was significantly different between the neuro-interventionalists and radiologists (p < 0.001), higher for the radiologists. The inter-rater reliability was excellent (ICC = 0.954, 95% CI: 0.898-0.979) between the 2 neuro-interventionalists, good between the 2 radiologists (ICC = 0.805, 95% CI: 0.418-0.921), but was not acceptable between the neuro-interventionalists and the radiologists (ICC 0.47 95% CI:-2.2-0.782). CONCLUSION: Despite the excellent agreement between the neuro-interventionists and the good agreement between the radiologists, there was no agreement between the neuro-interventionists and the radiologists. Our finding suggests that there is a gap between the 2 specialties but does not favor any of them. Factors related to the observers, the venous sinus system, the MRV or the CCS score may have resulted in this discrepancy. Automatic or semi-automatic feature extractions to produce quantifiable biomarkers for IIH are warranted. The clinical decisions should not depend only on strongly observer-dependent scores with training and/or experience-dependent influences.


Assuntos
Pseudotumor Cerebral , Humanos , Pseudotumor Cerebral/diagnóstico por imagem , Estudos Retrospectivos , Flebografia/métodos , Constrição Patológica/diagnóstico por imagem , Reprodutibilidade dos Testes , Cavidades Cranianas/diagnóstico por imagem , Espectroscopia de Ressonância Magnética
4.
Clin Radiol ; 78(2): e63-e70, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36307233

RESUMO

AIM: To compare the accuracy of three-dimensional (3D) high-resolution (HR) magnetic resonance imaging (MRI), time-of-flight magnetic resonance angiography (TOF-MRA), contrast-enhanced magnetic resonance angiography (CE-MRA), and digital subtraction angiography (DSA) in measuring the degree of stenosis in intracranial atherosclerosis. MATERIALS AND METHODS: All patients with intracranial artery ischaemic events underwent HR-MRI, TOF-MRA, and CE-MRA analysis, and some of these patients underwent DSA examination. The correlation between different methods for measuring the degree of lumen stenosis was analysed. The accuracy of HR-MRI, TOF-MRA, and CE-MRA was evaluated and compared with that of DSA. RESULTS: A total of 189 arterial stenoses were identified in 93 patients. Of these, 72 patients with 142 arterial stenoses underwent DSA examination. A very strong correlation between HR-MRI and CE-MRA measurements was shown (r=0.839, p<0.0001). The correlation between HR-MRI and TOF-MRA measurements was strong (r=0.720, p<0.0001). A very strong correlation between HR-MRI and DSA measurements was found (r=0.864, p<0.0001), and a similar correlation was observed between CE-MRA, and DSA measurements (r=0.843, p<0.0001). The correlation between TOF-MRA and DSA measurements was strong (r=0.686, p<0.0001). There was substantial agreement between HR-MRI and DSA measurements (K = 0.772) and between CE-MRA, and DSA measurements (K = 0.734) that was slightly higher than the agreement between TOF-MRA and DSA measurements (K = 0.636). CONCLUSION: HR-MRI can accurately measure stenosis (especially for moderate and severe stenosis) in intracranial atherosclerosis by direct visualisation of the vessel lumen and steno-occlusive plaque.


Assuntos
Aneurisma Intracraniano , Arteriosclerose Intracraniana , Humanos , Angiografia por Ressonância Magnética/métodos , Constrição Patológica/diagnóstico por imagem , Angiografia Digital/métodos , Imageamento Tridimensional/métodos , Arteriosclerose Intracraniana/diagnóstico por imagem , Sensibilidade e Especificidade , Meios de Contraste
5.
Pediatr Surg Int ; 38(12): 1769-1776, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36104600

RESUMO

PURPOSE: The severity of congenital tracheal stenosis (CTS) is commonly evaluated based on the degree of stenosis. However, it does not always reflect the clinical respiratory status. We applied computational fluid dynamics (CFD) to the assessment of CTS. The aim of this study was to evaluate its validity. METHODS: CFD models were constructed on 15 patients (12 preoperative models and 15 postoperative models) with CTS before and after surgery, using the computed tomographic data. Energy flux, needed to drive airflow, measured by CFD and the minimum cross-sectional area of the trachea (MCAT) were quantified and evaluated retrospectively. RESULTS: The energy flux correlated positively with the clinical respiratory status before and after surgery (rs = 0.611, p = 0.035 and rs = 0.591, p = 0.020, respectively). Although MCAT correlated negatively with the clinical respiratory status before surgery (rs = -0.578, p = 0.044), there was not significant correlation between the two after surgery (p = 0.572). CONCLUSIONS: The energy flux measured by CFD assessment reflects the respiratory status in CTS before and after surgery. CFD can be an additional objective and quantitative evaluation tool for CTS.


Assuntos
Procedimentos de Cirurgia Plástica , Estenose Traqueal , Humanos , Lactente , Traqueia/cirurgia , Estenose Traqueal/diagnóstico por imagem , Estenose Traqueal/cirurgia , Constrição Patológica/diagnóstico por imagem , Constrição Patológica/cirurgia , Hidrodinâmica , Estudos Retrospectivos , Resultado do Tratamento , Procedimentos de Cirurgia Plástica/métodos
6.
Ann Thorac Surg ; 113(5): 1624-1633, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34126076

RESUMO

BACKGROUND: Ultrasound is a reliable tool for airway assessment and management. We evaluated the accuracy of ultrasound in the preprocedure planning and follow-up evaluation of patients undergoing airway stenting for benign upper airway stenosis. METHODS: This was a retrospective single center study on patients with benign upper airway stenosis treated with airway stenting. Ultrasound evaluated the characteristics of the stenosis (distance from vocal folds, diameter, and length) before treatment and any complications after treatment; these results were then statistically compared with those obtained by computed tomography, taking the endoscopy as the reference method. RESULTS: Twenty-seven patients were evaluated. Ultrasound was significantly correlated with endoscopy and computed tomography scan measurements as distance of stenosis from vocal folds (r = 0.88; P < .001 and r = 0.87; P < .001, respectively), diameter of the stenosis (r = 0.97; P < .001 and r = 0.97; P < .001, respectively), and length of the stenosis (r = 0.97; P < .001 and r = 0.97; P < .001, respectively). Four out of 27 (15%) patients presented complications after treatment as stent migration (n = 2; 7%); stent obstruction (n = 1; 4%), and granulation of vocal fold (n = 1; 4%). All complications but granulation of vocal fold were correctly depicted by ultrasound and computed tomography without significant difference in comparison to endoscopy (P = .87) CONCLUSIONS: Ultrasound is a promising tool in assessment of airway stenosis and follow-up of patients after stenting; it may be routinely used in adjunction to computed tomography and/or endoscopy in this setting, if our results are corroborated by a future larger study.


Assuntos
Obstrução das Vias Respiratórias , Estenose Traqueal , Constrição Patológica/complicações , Constrição Patológica/diagnóstico por imagem , Constrição Patológica/cirurgia , Seguimentos , Humanos , Estudos Retrospectivos , Stents/efeitos adversos , Estenose Traqueal/diagnóstico por imagem , Estenose Traqueal/cirurgia , Resultado do Tratamento
7.
Phys Med ; 81: 210-214, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33477058

RESUMO

PURPOSE: This study aimed to investigate the potential of magnetic particle imaging (MPI) to quantify artificial stenoses in vessel phantoms in near real-time. METHODS: Custom-made stenosis phantoms with different degrees of stenosis (0%, 25%, 50%, 75%, and 100%; length 40 mm, inner diameter 8 mm, Polyoxymethylene) were filled with diluted Ferucarbotran (superparamagnetic iron-oxide nanoparticle (SPION) tracer agent, 500 mmol (Fe)/l). A traveling wave MPI scanner (spatial resolution ~ 2 mm, gradient strength ~ 1.5 T/m, field of view: 65 mm length and 29 mm diameter, frequencies f1 = 1050 Hz and f2 = 12150 Hz) was used to acquire images of the phantoms (200 ms total acquisition time per image, 10 averages). Standardized grey scaling was used for comparability. All measured stenoses (n = 80) were graded manually using a dedicated software tool. RESULTS: MPI allowed for accurate visualization of stenoses at a frame rate of 5frames per second. Less severe stenoses were detected more precisely than higher-grade stenoses and came with smaller standard deviations. In particular, the 0%, 25%, 50%, 75%, and 100% stenosis phantom were measured as 3.7 ± 2.7% (mean ± standarddeviation), 18.6 ± 1.8%, 52.8 ± 3.7%, 77.8 ± 14.8% and 100 ± 0%. Geometrical distortions occurred around the center of the high-grade stenosis and led to higher standard deviations compared to lower grade stenoses. In the frame of this study the MPI signal depended linearly on the SPION concentration down to 0.05 mmol (Fe)/l. CONCLUSION: Near real-time MPI accurately visualized and quantified different stenosis grades in vascular phantoms.


Assuntos
Diagnóstico por Imagem , Modelos Teóricos , Constrição Patológica/diagnóstico por imagem , Humanos , Fenômenos Magnéticos , Imagens de Fantasmas
8.
Eur Radiol ; 31(5): 2778-2787, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33068186

RESUMO

OBJECTIVES: The proton density-weighted, in-phase stack-of-stars (PDIP-SOS) MRI technique provides calcification visualization in peripheral artery disease (PAD). This study sought to investigate the diagnostic accuracy of a combined non-contrast quiescent-interval slice-selective (QISS) MRA and PDIP-SOS MRI protocol for the detection of PAD, in comparison with CTA and digital subtraction angiography (DSA). METHODS: Twenty-six prospectively enrolled PAD patients (70 ± 8 years) underwent lower extremity CTA and 1.5-T or 3-T PDIP-SOS/QISS MRI prior to DSA. Two readers rated image quality and graded stenosis (≥ 50%) on QISS MRA without/with calcification visualization. Sensitivity, specificity, and area under the curve (AUC) were calculated against DSA. Calcification was quantified and compared between MRI and non-contrast CT (NCCT) using paired t test, Pearson's correlation, and Bland-Altman analysis. RESULTS: Image quality ratings were significantly higher for CTA compared to those for MRA (4.0 [3.0-4.0] and 3.0 [3.0-4.0]; p = 0.0369). The sensitivity and specificity of QISS MRA, QISS MRA with PDIP-SOS, and CTA for ≥ 50% stenosis detection were 85.4%, 92.2%, and 90.2%, and 90.3%, 93.2%, and 94.2%, respectively, while AUCs were 0.879, 0.928, and 0.923, respectively. A significant increase in AUC was observed when PDIP-SOS was added to the MRA protocol (p = 0.0266). Quantification of calcification showed significant differences between PDIP-SOS and NCCT (80.6 ± 31.2 mm3 vs. 88.0 ± 29.8 mm3; p = 0.0002) with high correlation (r = 0.77, p < 0.0001) and moderate mean of differences (- 7.4 mm3). CONCLUSION: QISS MRA combined with PDIP-SOS MRI provides improved, CTA equivalent, accuracy for the detection of PAD, although its image quality remains inferior to CTA. KEY POINTS: • Agreement in stenosis detection rate using non-contrast quiescent-interval slice-selective MRA compared to DSA improved when calcification visualization was provided to the readers. • An increase was observed in both sensitivity and specificity for the detection of ≥ 50% stenosis when MRI-based calcification assessment was added to the protocol, resulting in a diagnostic accuracy more comparable to CTA. • Quantification of calcification showed statistical difference between MRI and non-contrast CT; however, a high correlation was observed between the techniques.


Assuntos
Doença Arterial Periférica , Calcificação Vascular , Angiografia Digital , Constrição Patológica/diagnóstico por imagem , Meios de Contraste , Humanos , Extremidade Inferior/diagnóstico por imagem , Angiografia por Ressonância Magnética , Imageamento por Ressonância Magnética , Doença Arterial Periférica/complicações , Doença Arterial Periférica/diagnóstico por imagem , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Calcificação Vascular/complicações , Calcificação Vascular/diagnóstico por imagem
9.
Cochrane Database Syst Rev ; 2: CD010722, 2020 02 19.
Artigo em Inglês | MEDLINE | ID: mdl-32072609

RESUMO

BACKGROUND: An occlusion or stenosis of intracranial large arteries can be detected in the acute phase of ischaemic stroke in about 42% of patients. The approved therapies for acute ischaemic stroke are thrombolysis with intravenous recombinant tissue plasminogen activator (rt-PA), and mechanical thrombectomy; both aim to recanalise an occluded intracranial artery. The reference standard for the diagnosis of intracranial stenosis and occlusion is intra-arterial angiography (IA) and, recently, computed tomography angiography (CTA) and magnetic resonance angiography (MRA), or contrast-enhanced MRA. Transcranial Doppler (TCD) and transcranial colour Doppler (TCCD) are useful, rapid, noninvasive tools for the assessment of intracranial large arteries pathology. Due to the current lack of consensus regarding the use of TCD and TCCD in clinical practice, we systematically reviewed the literature for studies assessing the diagnostic accuracy of these techniques compared with intra-arterial IA, CTA, and MRA for the detection of intracranial stenosis and occlusion in people presenting with symptoms of ischaemic stroke. OBJECTIVES: To assess the diagnostic accuracy of TCD and TCCD for detecting stenosis and occlusion of intracranial large arteries in people with acute ischaemic stroke. SEARCH METHODS: We limited our searches from January 1982 onwards as the transcranial Doppler technique was only introduced into clinical practice in the 1980s. We searched MEDLINE (Ovid) (from 1982 to 2018); Embase (Ovid) (from 1982 to 2018); Database of Abstracts of Reviews of Effects (DARE); and Health Technology Assessment Database (HTA) (from 1982 to 2018). Moreover, we perused the reference lists of all retrieved articles and of previously published relevant review articles, handsearched relevant conference proceedings, searched relevant websites, and contacted experts in the field. SELECTION CRITERIA: We included all studies comparing TCD or TCCD (index tests) with IA, CTA, MRA, or contrast-enhanced MRA (reference standards) in people with acute ischaemic stroke, where all participants underwent both the index test and the reference standard within 24 hours of symptom onset. We included prospective cohort studies and randomised studies of test comparisons. We also considered retrospective studies eligible for inclusion where the original population sample was recruited prospectively but the results were analysed retrospectively. DATA COLLECTION AND ANALYSIS: At least two review authors independently screened the titles and abstracts identified by the search strategies, applied the inclusion criteria, extracted data, assessed methodological quality (using QUADAS-2), and investigated heterogeneity. We contacted study authors for missing data. MAIN RESULTS: A comprehensive search of major relevant electronic databases (MEDLINE and Embase) from 1982 to 13 March 2018 yielded 13,534 articles, of which nine were deemed eligible for inclusion. The studies included a total of 493 participants. The mean age of included participants was 64.2 years (range 55.8 to 69.9 years). The proportion of men and women was similar across studies. Six studies recruited participants in Europe, one in south America, one in China, and one in Egypt. Risk of bias was high for participant selection but low for flow, timing, index and reference standard. The summary sensitivity and specificity estimates for TCD and TCCD were 95% (95% CI = 0.83 to 0.99) and 95% (95% CI = 0.90 to 0.98), respectively. Considering a prevalence of stenosis or occlusion of 42% (as reported in the literature), for every 1000 people who receive a TCD or TCCD test, stenosis or occlusion will be missed in 21 people (95% CI = 4 to 71) and 29 (95% CI = 12 to 58) will be wrongly diagnosed as harbouring an intracranial occlusion. However, there was substantial heterogeneity between studies, which was no longer evident when only occlusion of the MCA was considered, or when the analysis was limited to participants investigated within six hours. The performance of either TCD or TCCD in ruling in and ruling out a MCA occlusion was good. Limitations of this review were the small number of identified studies and the lack of data on the use of ultrasound contrast medium. AUTHORS' CONCLUSIONS: This review provides evidence that TCD or TCCD, administered by professionals with adequate experience and skills, can provide useful diagnostic information for detecting stenosis or occlusion of intracranial vessels in people with acute ischaemic stroke, or guide the request for more invasive vascular neuroimaging, especially where CT or MR-based vascular imaging are not immediately available. More studies are needed to confirm or refute the results of this review in a larger sample of stroke patients, to verify the role of contrast medium and to evaluate the clinical advantage of the use of ultrasound.


Assuntos
Isquemia Encefálica/diagnóstico por imagem , Constrição Patológica/diagnóstico por imagem , Acidente Vascular Cerebral/diagnóstico por imagem , Ultrassonografia Doppler Transcraniana/métodos , Artérias Cerebrais/diagnóstico por imagem , Humanos , Infarto da Artéria Cerebral Média , Ensaios Clínicos Controlados Aleatórios como Assunto
10.
Skeletal Radiol ; 49(1): 75-83, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31240381

RESUMO

OBJECTIVE: To propose a novel morphological classification method for notches, which may provide new evidence for notchplasty based on the three-dimensional (3D) features of notches and the risk of anterior cruciate ligament (ACL) injury. MATERIALS AND METHODS: Three hundred individuals in total were included in our study, including 150 patients with ACL ruptures (75 males and 75 females) and 150 age- and gender-matched individuals without ACL ruptures. The notches were divided into four types according to the notch widths at the notch inlet, outlet, and ACL attachment based on the preoperative MRI, the notch volume was calculated, and the risk of ACL injury was compared. The surgical records were reviewed and whether these cases performed notchplasty were collected. RESULTS: The inlet-and-outlet stenosis notch type was associated with smaller notch volume (P = 0.007) and a higher risk of ACL injury (P < 0.001). There were no significant differences in morphological distribution between males and females. The rate of notchplasty in inlet-and-outlet stenosis type was higher than the others. CONCLUSIONS: The new morphological classification method efficiently reflected the association of the notch shape with the 3D notch volume and the risk of ACL injury. The knees with the inlet-and-outlet stenosis notch type and smaller notch volume tended to have a higher risk of ACL injury. Level of evidence Level III, case-control study.


Assuntos
Lesões do Ligamento Cruzado Anterior/diagnóstico por imagem , Constrição Patológica/classificação , Fêmur/diagnóstico por imagem , Articulação do Joelho/diagnóstico por imagem , Adolescente , Adulto , Constrição Patológica/diagnóstico por imagem , Feminino , Fêmur/anormalidades , Fêmur/anatomia & histologia , Humanos , Imageamento Tridimensional , Articulação do Joelho/anatomia & histologia , Imageamento por Ressonância Magnética , Masculino , Estudos Retrospectivos , Fatores de Risco , Adulto Jovem
11.
J Neurointerv Surg ; 12(3): 311-314, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31772041

RESUMO

OBJECTIVE: Intracranial venous sinus stenosis (IVSS) is the most common finding associated with idiopathic intracranial hypertension. A pressure gradient >8-10 mm Hg across the stenosis is considered hemodynamically significant, and typically responds to endovascular stent treatment. Here we assess the venous hemodynamics with two-dimensional (2D) parametric parenchymal blood flow software (Siemens-Healthineers, Forchheim, Germany) and its ability to predict significant IVSS. METHODS: Patients with IVSS treated at our institution between 2013 and 2018 were retrospectively reviewed. Measurements of contrast transit time on DSA were calculated with 2D parametric parenchymal blood flow software. Values were obtained proximally and distally to the stenotic region. Venous Stenosis Index (VSI) was defined as the ratio of the area under the curve (AUC) in the pre-stenotic vessel to the AUC in the post-stenotic vessel. VSI was compared between the stenotic and control groups at baseline, and before and after stent deployment in the stenotic group. The accuracy of VSI was assessed using the non-parametric receiver operating characteristic (ROC) curve. RESULTS: 11 patients with IVSS treated with venous stent deployment were included. Patients in the control group were similar in age, gender, and absence of major comorbidities. VSI in the IVSS group was significantly higher at baseline compared with the control group (1.42 vs 0.97, p=0.01). Area under the ROC was 0.82. After stent deployment, VSI decreased significantly compared with baseline (1.04 vs 1.42, p<0.01). CONCLUSION: 2D parametric parenchymal blood flow software is a useful tool which can accurately evaluate significant hemodynamic venous stenosis without intracranial catheterization, added radiation exposure, additional contrast injection, and periprocedural risks.


Assuntos
Angiografia Digital/métodos , Circulação Cerebrovascular/fisiologia , Transtornos Cerebrovasculares/diagnóstico por imagem , Cavidades Cranianas/diagnóstico por imagem , Hemodinâmica/fisiologia , Software , Adolescente , Adulto , Idoso , Transtornos Cerebrovasculares/fisiopatologia , Constrição Patológica/diagnóstico por imagem , Constrição Patológica/fisiopatologia , Cavidades Cranianas/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Stents , Adulto Jovem
12.
J Neuroimaging ; 29(4): 467-475, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30950158

RESUMO

BACKGROUND AND PURPOSE: Hemodynamic and metabolic impairment in intracranial atherosclerotic stenosis (ICAS) may promote stroke vulnerability particularly in borderzone areas. Perfusion and oxygen mapping magnetic resonance imaging (MRI) may provide useful information in this setting. METHODS: In this pilot study, patients with symptomatic atherosclerotic anterior circulation stenosis ≥60%, without other sources of ischemic stroke, were included. High-resolution vessel wall MRI quantified the stenosis degree, and hemodynamic and metabolic impairment was assessed at baseline using dynamic susceptibility contrast perfusion and multiparametric quantitative blood-oxygen-level-dependent (mqBOLD) oxygenation MRI. All parameters were assessed within both hemispheres and in borderzone areas. RESULTS: Forty-three subjects with intracranial artery narrowing were screened from November 2014 to January 2016. Eleven patients met the study criteria (mean ± standard deviation age = 64.4 ± 10.6 years, the mean degree of stenosis was 76.9 ± 23.4%). No interhemispheric differences were observed across oxygen (cerebral metabolic rate of oxygen and tissular saturation of oxygen) or perfusion (mean transit time, time to maximum, Tmax , normalized cerebral blood volume [nCBV], and normalized cerebral blood flow) parameters. A positive correlation was observed between the stenosis degree and ipsilateral nCBV (R = .77, P = .008). In addition, a significant increase in CBV was observed in anterior cortical borderzones ipsilateral to stenosis (nCBV = 7.20 ± 1.81 vs. 5.45 ± 1.40 mL/100 g, P = .02). CONCLUSION: Symptomatic ICAS had no global impact on perfusion and oxygen mapping MRI at resting state. A significant increase in nCBV was found within anterior borderzone areas.


Assuntos
Arteriosclerose Intracraniana/diagnóstico por imagem , Acidente Vascular Cerebral/diagnóstico por imagem , Idoso , Circulação Cerebrovascular/fisiologia , Constrição Patológica/diagnóstico por imagem , Constrição Patológica/metabolismo , Feminino , Hemodinâmica/fisiologia , Humanos , Arteriosclerose Intracraniana/metabolismo , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Oxigênio , Projetos Piloto , Acidente Vascular Cerebral/metabolismo
13.
Gut ; 68(6): 1115-1126, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30944110

RESUMO

Patients with Crohn's disease commonly develop ileal and less commonly colonic strictures, containing various degrees of inflammation and fibrosis. While predominantly inflammatory strictures may benefit from a medical anti-inflammatory treatment, predominantly fibrotic strictures currently require endoscopic balloon dilation or surgery. Therefore, differentiation of the main components of a stricturing lesion is key for defining the therapeutic management. The role of endoscopy to diagnose the nature of strictures is limited by the superficial inspection of the intestinal mucosa, the lack of depth of mucosal biopsies and by the risk of sampling error due to a heterogeneous distribution of inflammation and fibrosis within a stricturing lesion. These limitations may be in part overcome by cross-sectional imaging techniques such as ultrasound, CT and MRI, allowing for a full thickness evaluation of the bowel wall and associated abnormalities. This systematic literature review provides a comprehensive summary of currently used radiologic definitions of strictures. It discusses, by assessing only manuscripts with histopathology as a gold standard, the accuracy for diagnosis of the respective modalities as well as their capability to characterise strictures in terms of inflammation and fibrosis. Definitions for strictures on cross-sectional imaging are heterogeneous; however, accuracy for stricture diagnosis is very high. Although conventional cross-sectional imaging techniques have been reported to distinguish inflammation from fibrosis and grade their severity, they are not sufficiently accurate for use in routine clinical practice. Finally, we present recent consensus recommendations and highlight experimental techniques that may overcome the limitations of current technologies.


Assuntos
Doença de Crohn/epidemiologia , Obstrução Intestinal/epidemiologia , Intestino Delgado/patologia , Imagem Multimodal/métodos , Comorbidade , Constrição Patológica/diagnóstico por imagem , Constrição Patológica/epidemiologia , Constrição Patológica/patologia , Doença de Crohn/diagnóstico por imagem , Doença de Crohn/patologia , Estudos Transversais , Técnicas de Imagem por Elasticidade/métodos , Feminino , Fibrose/diagnóstico por imagem , Fibrose/epidemiologia , Humanos , Incidência , Obstrução Intestinal/diagnóstico por imagem , Obstrução Intestinal/patologia , Intestino Delgado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Masculino , Prognóstico , Medição de Risco , Tomografia Computadorizada por Raios X/métodos , Ultrassonografia Doppler/métodos
14.
J Ultrasound Med ; 38(11): 2935-2943, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30907015

RESUMO

OBJECTIVES: Parotid duct stenosis may occur with or without accompanying ductal anomalies, with associated differences in their pathogenesis and management. By identifying the characteristics of a stenosis, ultrasound (US) can assist in tailored management of parotid duct stenosis. The objective of this study was therefore to describe the US characteristics of parotid duct stenoses and to evaluate criteria for whether and in what ways these can be distinguished from each other by using US. METHODS: A total of 108 patients who presented with parotid duct stenoses (130 parotid glands) were examined with high-resolution US between 2014 and 2017. The stenoses were assessed for duct dilatation, location, signs of ductal anomalies (circular encroachments/webs, duct bending/kinking, and presence of a megaduct) and the echogenicity of the gland parenchyma. RESULTS: Ultrasound was able to distinguish between stenoses associated with ductal anomalies and those without anomalies. Webs (82.5% versus 7.8%; P < .001), kinking (75.0% versus 3.3%; P < .001), and a megaduct (87.50% versus 15.63%; P < .001) and a tendency toward normal echogenicity in the gland parenchyma (77.5% versus 25.6%; P < .001) were significantly associated with ductal anomalies. Stenoses associated with ductal anomalies also had significantly larger duct diameters in comparison with those without anomalies (mean ± SD, 9.19 ± 3.65 versus 3.27 ± 2.17 mm; P < .001). CONCLUSIONS: This study describes US parameters that allow more detailed characterization of parotid stenoses with or without accompanying ductal anomalies. Differentiating between these at an early stage may be helpful for decision making on the further management in these patients.


Assuntos
Glândula Parótida/diagnóstico por imagem , Glândula Parótida/patologia , Doenças das Glândulas Salivares/diagnóstico por imagem , Doenças das Glândulas Salivares/patologia , Ultrassonografia/métodos , Constrição Patológica/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
15.
J Magn Reson Imaging ; 49(1): 229-238, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-29707848

RESUMO

BACKGROUND: Improving the signal-to-noise ratio (SNR) of chemical-shift-encoded MRI acquisition with complex reconstruction (MRI-C) may improve the accuracy and precision of noninvasive proton density fat fraction (PDFF) quantification in patients with hepatic steatosis. PURPOSE: To assess the accuracy of high SNR (Hi-SNR) MRI-C versus standard MRI-C acquisition to estimate hepatic PDFF in adult and pediatric nonalcoholic fatty liver disease (NAFLD) using an MR spectroscopy (MRS) sequence as the reference standard. STUDY TYPE: Prospective. POPULATION/SUBJECTS: In all, 231 adult and pediatric patients with known or suspected NAFLD. FIELD STRENGTH/SEQUENCE: PDFF estimated at 3T by three MR techniques: standard MRI-C; a Hi-SNR MRI-C variant with increased slice thickness, decreased matrix size, and no parallel imaging; and MRS (reference standard). ASSESSMENT: MRI-PDFF was measured by image analysts using a region of interest coregistered with the MRS-PDFF voxel. STATISTICAL TESTS: Linear regression analyses were used to assess accuracy and precision of MRI-estimated PDFF for MRS-PDFF as a function of MRI-PDFF using the standard and Hi-SNR MRI-C for all patients and for patients with MRS-PDFF <10%. RESULTS: In all, 271 exams from 231 patients were included (mean MRS-PDFF: 12.6% [SD: 10.4]; range: 0.9-41.9). High agreement between MRI-PDFF and MRS-PDFF was demonstrated across the overall range of PDFF, with a regression slope of 1.035 for the standard MRI-C and 1.008 for Hi-SNR MRI-C. Hi-SNR MRI-C, compared to standard MRI-C, provided small but statistically significant improvements in the slope (respectively, 1.008 vs. 1.035, P = 0.004) and mean bias (0.412 vs. 0.673, P < 0.0001) overall. In the low-fat patients only, Hi-SNR MRI-C provided improvements in the slope (1.058 vs. 1.190, P = 0.002), mean bias (0.168 vs. 0.368, P = 0.007), intercept (-0.153 vs. -0.796, P < 0.0001), and borderline improvement in the R2 (0.888 vs. 0.813, P = 0.01). DATA CONCLUSION: Compared to standard MRI-C, Hi-SNR MRI-C provides slightly higher MRI-PDFF estimation accuracy across the overall range of PDFF and improves both accuracy and precision in the low PDFF range. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;49:229-238.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Constrição Patológica/diagnóstico por imagem , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Razão Sinal-Ruído , Adolescente , Adulto , Idoso , Criança , Estudos Transversais , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Prótons , Padrões de Referência , Análise de Regressão , Reprodutibilidade dos Testes , Adulto Jovem
16.
J Crohns Colitis ; 13(5): 607-614, 2019 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-30541145

RESUMO

BACKGROUND: Crohns disease [CD] is a chronic inflammation in the gut that often progresses to fibrosis. Magnetic resonance enterography [MRE] is an important diagnostic tool in evaluating CD. We aimed to assess the prevalence of inflammation and stricturing disease in patients with long-term CD, and to investigate associations with clinical factors. METHODS: We performed a follow-up analysis of a population-based cohort of 237 CD patients in south-eastern Norway 20 years after diagnosis; 95 patients were examined with MRE, and the magnetic enterographic global score [MEGS] was calculated. We assessed inflammation and strictures during the follow-up. Association of the MEGS and bowel strictures with clinical variables was examined by univariate regression analysis. RESULTS: Of the 237 patients, 62 [65.3%] had active inflammation mostly affecting the terminal ileum; 35 [36.8%] had substantial inflammation according to MEGS, which associated with inflammatory biomarkers during the follow-up; and 25 [26.3%] had stricturing disease that associated with age (odds ratio [OR] = 0.92), initial use of systemic steroids [OR = 3.36], and inflammatory biomarkers. Most patients with strictures were treated with surgery without recurrence [n = 24, 42.1%] and seven [21.2%] strictures in the terminal ileum healed without surgery. CONCLUSIONS: Twenty years after the diagnosis, the majority of patients had active inflammation, often complicated by stricturing disease. Most patients with strictures were treated with surgery without recurrence, and some strictures resolved over time. Inflammatory biomarkers, extensive and complicated disease type, and use of systemic medication associated with both inflammation and stricturing disease.


Assuntos
Doença de Crohn/diagnóstico por imagem , Intestinos/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Constrição Patológica/diagnóstico por imagem , Constrição Patológica/patologia , Doença de Crohn/patologia , Feminino , Humanos , Inflamação/diagnóstico por imagem , Inflamação/patologia , Intestinos/patologia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade
17.
Respiration ; 97(2): 108-118, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30293066

RESUMO

BACKGROUND: Congenital cardiovascular malformations (CCVM) may cause infrequently airway pathologies (AP) in children and are of prognostic and therapeutic relevance. While computed tomography (CT) is considered first-line imaging modality in many centres, we started using magnetic resonance imaging (MRI) more and more in the last years to detect CCVM and AP to avoid radiation in this patient group. OBJECTIVE: The aim of this retrospective study was to determine and to compare the diagnostic accuracy of CT and MRI when used to detect CCVM and/or AP. METHODS: All patients suspected to have CCVM and/or AP and examined either by CT or MRI between 2000 and 2013 in our hospital were included. Extension and type of CCVM, as well as their relationship to esophagus, trachea or bronchi were assessed and related to findings of tracheobronchoscopy, cardiac catheterization or surgery if available. RESULTS: One hundred six patients (median [range] 4 years [2 days to 66 years]) were examined by CT (n = 27) or MRI (n = 79). In 78 patients (74%), CCVM and/or AP were found with either of the imaging methods. CCVM were found in 63 subjects. Forty-six of 63 subjects had both, CCVM and AP. The presence of CCVM was always detected correctly by CT or MRI, although both techniques had a weakness detecting atretic segments directly. AP (n = 61) were correctly diagnosed in all patients not intubated for artificial ventilation by CT (n = 17) and in all but 2 patients by MRI (39 out of 41). CONCLUSIONS: MRI is sensitive to detect CCVM associated with AP equally to CT without any radiation exposure.


Assuntos
Cardiopatias Congênitas/diagnóstico por imagem , Imageamento por Ressonância Magnética , Tomografia Computadorizada Multidetectores , Anel Vascular/diagnóstico por imagem , Adolescente , Adulto , Idoso , Broncopatias/diagnóstico por imagem , Criança , Pré-Escolar , Constrição Patológica/diagnóstico por imagem , Esôfago/diagnóstico por imagem , Feminino , Humanos , Imageamento Tridimensional , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Traqueia/diagnóstico por imagem , Estenose Traqueal/diagnóstico por imagem , Traqueobroncomalácia/diagnóstico por imagem , Adulto Jovem
18.
J Med Case Rep ; 12(1): 92, 2018 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-29642943

RESUMO

BACKGROUND: Celiac axis stenosis due to compression by the median arcuate ligament has been reported in patients undergoing pancreaticoduodenectomy; it leads to the development of major collateral pathways that feed the hepatic artery. Dividing these important collaterals during pancreaticoduodenectomy can cause ischemic complications which may lead to a high mortality rate. To prevent these complications, it is necessary to assess intrahepatic arterial flow. CASE PRESENTATION: A 71-year-old Japanese man with anorexia was referred to us for the treatment of alcoholic chronic pancreatitis. Computed tomography revealed a pancreatic head tumor with a calculus, associated with the dilatation of the main pancreatic duct and intrahepatic bile duct. Three-dimensional imaging demonstrated focal narrowing in the proximal celiac axis due to median arcuate ligament compression and a prominent gastroduodenal artery that fed the common hepatic artery. The preoperative diagnosis was alcoholic chronic pancreatitis with common bile duct obstruction and celiac axis stenosis due to median arcuate ligament compression. Pancreaticoduodenectomy with median arcuate ligament release was scheduled. Before the division of the median arcuate ligament, the peak flow velocity and resistive index of his intrahepatic artery measured with Doppler ultrasonography decreased from 37.7 cm/second and 0.510, respectively, to 20.6 cm/second and 0.508 respectively, when his gastroduodenal artery was clamped. However, these values returned to baseline levels after the division of the median arcuate ligament. These findings suggested that pancreaticoduodenectomy could be performed safely. Our patient was discharged on postoperative day 17 without significant complications. CONCLUSION: The intraoperative quantitative evaluation of intrahepatic arterial blood flow using Doppler ultrasonography was useful in a patient who underwent pancreaticoduodenectomy, who had celiac axis stenosis due to compression by the median arcuate ligament.


Assuntos
Arteriopatias Oclusivas/cirurgia , Artéria Celíaca/diagnóstico por imagem , Artéria Hepática/diagnóstico por imagem , Síndrome do Ligamento Arqueado Mediano/etiologia , Pancreaticoduodenectomia/efeitos adversos , Idoso , Arteriopatias Oclusivas/complicações , Arteriopatias Oclusivas/diagnóstico , Arteriopatias Oclusivas/fisiopatologia , Artéria Celíaca/patologia , Ducto Colédoco/irrigação sanguínea , Constrição Patológica/diagnóstico por imagem , Constrição Patológica/etiologia , Artéria Hepática/patologia , Humanos , Imageamento Tridimensional , Circulação Hepática , Masculino , Síndrome do Ligamento Arqueado Mediano/diagnóstico por imagem , Síndrome do Ligamento Arqueado Mediano/cirurgia , Pancreatite Alcoólica/complicações , Ultrassonografia Doppler
19.
Int J Cardiol ; 260: 178-183, 2018 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-29622435

RESUMO

BACKGROUND: Although reactive hyperemia-peripheral arterial tonometry (RH-PAT) is widely used for assessment of endothelial function, RH index (RHI) cannot be measured in some cases when pulse wave amplitude (PWA) is very low. Decrease in PWA is mainly caused by proper palmar digital artery (PPDA) stenosis. The purpose of this study was to evaluate the relationship between PWA measured by RH-PAT and stenosis of the PPDA measured by digital subtraction angiography and to evaluate the limitation of assessment of endothelial function measured by RHI in patients with PPDA stenosis. METHODS: We measured baseline PWA in 51 fingers including the first to third fingers of both hands in 10 patients who had PPDA stenosis and in 66 fingers that were the first fingers of both hands in 33 subjects who had no PPDA stenosis. Severe stenosis was defined as over 75% by lower percent diameter stenosis between two PPDAs in a finger. RESULTS: PWA was significantly correlated with stenosis of the digital artery (r=-0.55; P<0.0001). A PWV value of 300mV was the optimal cut-off value for severe stenosis (sensitivity, 84.0%; specificity, 88.5%). Log RHI was significantly lower in patients with PPDA stenosis than in subjects without PPDA stenosis (0.33±0.27 versus 0.73±0.27, P=0.007). CONCLUSIONS: RH-PAT may be useful for assessment of not only endothelial function but also PPDA stenosis. RHI may be underestimated in patients with PPDA stenosis. We should pay attention to low baseline PWA when measuring RHI. CLINICAL TRIAL REGISTRATION INFORMATION: URL for clinical trial: http://UMIN; registration number for clinical trial: UMIN000003409.


Assuntos
Endotélio Vascular/diagnóstico por imagem , Hiperemia/diagnóstico por imagem , Manometria/métodos , Doença Arterial Periférica/diagnóstico por imagem , Artéria Ulnar/diagnóstico por imagem , Adulto , Idoso , Angiografia Digital/métodos , Constrição Patológica/diagnóstico por imagem , Constrição Patológica/fisiopatologia , Endotélio Vascular/fisiologia , Feminino , Humanos , Hiperemia/fisiopatologia , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/fisiopatologia , Artéria Ulnar/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA